G.K. Enterprises provides complete solutions for Industrial and Domestic Heat Tracing applications. Making the system more efficient, getting quality products or making your life style more comfortable, the following product finds its uses depending upon the need and application. Heating cables have been categorized as follows:-
Constant Wattage Series Circuit
| S. No. | Element | Detail | Advantage |
| 1 | Heating element | Spirally wound Nicrome wire on glass fiber cord. | Very low temp. coefficient Good Tensile Strength |
| 2 | Insulation | Tape Wrapped PTFE | Max. temp. 260 Deg.C |
| 3 | Shielding | S.S. braid | For Earthing and Mechanical Protection |
| 4 | Cold Lead | PTFE insulated SPC wire | Low Contact resistance |
Supply Voltage: 230 V AC (Other rated voltages can also be designed)
Minimum environment temperature: Minus 55 deg.C
Minimum operating surface temperature: + 260 deg.C
Maximum bending radius: 6 x diameter
Minimum Resistant: Yes
Minimum O.D. : 3.0 mm ( Diameter at joints is higher)
Type of joint: Water proof| Part No. | Wattage watt/m | Max. Operating Temp.(deg.C) | Max. Diameter (mm) | Heater Length (m)* |
| CWST10 | 10 |
260 | 3 | According to Customer |
| CWST20 | 20 | 260 | 3 | requirement |