Products

G.K. Enterprises provides complete solutions for Industrial and Domestic Heat Tracing applications. Making the system more efficient, getting quality products or making your life style more comfortable, the following product finds its uses depending upon the need and application. Heating cables have been categorized as follows:-

Constant Wattage Parallel Circuit

The parallel bus wires supply voltage along the entire length of the heater cable. A resistance wire heating element is spirally wrapped around bus wires contacting alternate bus wires at specific intervals forming heating zones. This series of parallel heating zones provides a constant power output for each zone, irrespective of where the cable is cut along the length of the bus wire. There is no change of power output with the change in temperature, anywhere in its recommended operating range.



Characteristics :-
Strong but flexible
No returning lead is required
Flat configuration enables efficient heat transfer.
Cut to length at site; no wastage
Easy termination and installation
Integrated cold end without joints
No inrush current

A. Low Temperature Cable Construction

S. No. Element Detail Advantage
1. Two parallel bus wire 1.5 sq. mm multistrand
tin plated Copper
Flexible, Easy to Solder
Max. temp. 150 Deg.C
2. Primary Insulation HR PVC Max. temp. 105 Deg.C
3. Heating element Nicrome wire Very low temp. coefficient
4. Secondary Insulation HR PVC Max. temp. 105 Deg.C
5. Shielding Nickel Plated Copper braid Chemical resistant Max. temp. 260 Deg.C
6. Jacket (Optional) HR PVC For Corrosive Environment


Technical Data: -
Supply Voltage: 230 V (Other rated voltages can also be designed
Minimum environment temperature: Miuns deg.C
Minimum bending radius : 40 mm
Maximum Temperature withstand : 80 Deg. C
Minimum Space between turns : 40 mm (Should not be

Range :-

Part No. Wattage watt/m Max. Length (m) Zone Length (m) Max. Operating Temp. (deg.C)
CWPT10 10
150 1.50 180
CWPT20 20 125 1.00 150
CWPT30 30 100 1.00 140
CWPT40 40 75 1.00 120

B. High Temperature Cable Construction

S. No. Element Detail Advantage
1. Two parallel bus wire 1.5 sq. mm multistrand silver plated Copper Flexible, Easy to Solder Max. temp. 200 Deg.C
2. Primary Insulation Tape Wrapped sintered PTFE Max. temp. 260 Deg.C
3. Heating element Nicrome wire Very low temp. coefficient
4. Secondary Insulation Tape Wrapped sintered PTFE Max. temp. 260 Deg.C
5. Shielding Nickel Plated Copper braid Chemical resistant Max. temp. 260 Deg.C
6. Jacket (Optional) Tape Wrapped sintered PTFE For Corrosive Environment

Technical Data: -
Supply Voltage: 230 V (Other rated voltages can also be designed)
MInimum environment temperature: Miuns deg.C
MInimum bending radius: 30 mm
Moisture Resistant : Yes
Muximum Temperature withstand : + 240 Deg. C
Munimum Space between turns : 25 mm (Should not be

Range:-

Part No. Wattage watt/m Max. Length (m) Zone Length (m) Max. Operating Temp. (deg.C)
CWPP10 10
150 1.50 40
CWPP20 20 110 1.00 35

Copyright 2007 © GK Enterprises Pvt. Ltd.